EZ-Pro Oil Burners

Advanced Oil Burners
0.5 to 2.6 GPH

[Photo] EZ-1 (EZ123)

Available with or without a burner cover. The EZ-Pro advanced oil burner combines the proven range and reliability of the EZ burner with Carlin’s line of electronic controls and high efficiency components. Purchase the EZ-Pro in any of three configurations – EZ-1, EZ-2, or EZ-3. Specify tube length when ordering.

Input
EZ-1: 0.5 to 1.65 GPH
EZ-2: 1.50 to 2.25 GPH
EZ-3: 2.00 to 2.50 GPH
Fuels
U.S. – No. 1 or No. 2 Fuel Oil
Canada – No. 1 Oil or No. 2 Furnace Oil
Electrical
Power: 120 vac, 60Hz, 1-Phase
Current: Approximately 5.8 Amps
Limit Circuit Input: 120 vac, 60 Hz
Motor (PSC): 1/6 HP, 3450 RPM
Motor Frame: 48-Frame, “M” Flange
Oil Valve Power: 120 vac, 60 Hz
Nozzle Line Heater: 120 vac, 60 Hz
Alarm Contacts (Isolated): 24 VAC/VDC, 2 Amps
Ignition
Carlin Model 41000 solid state electronic ignition
Ignition Voltage: 14,000 volts
Control
Carlin Model 60200 Microprocessor Control
15 sec. Trial for Ignition (TFI)
1.3 sec. FFRT
Pre-purge and post-purge (10 seconds)
Serviceman reset protection (Latch-up after three consecutive lockouts)
Interrupted Duty Ignition
Recycle on flame failure
Operating Temperature Limits
Maximum Ambient: 104° F (40° C)
Agencies
UL Listed: US & Canada