Pro-X 70200

Universal Oil Primary Control

Pro-X 70200 Control:

• Replaces virtually any oil primary control
• Pinpoints cause of burner faults for fast, accurate repairs
• Provides built-in alarm contacts

Features & Benefits:

• Last Fault Alert – Displays fault reason, even if homeowner resets control
• Larger LCD Display – For improved visibility
• Improved Menu Options – Simplifies setup and navigation
• Recessed Wiring Terminals – Added wiring space in j-box
• Communications Capable – Remote monitoring and alerts
• Low Voltage Blocked Vent Contacts – Allows for easy connections

 

Power Input (Red/White Wire)

  120
vac, 60 Hz, 9 VA

Limit Circuit Input (Black Wire)

  120vac, 60 Hz
Motor Load
  10 FLA / 60 LRA (reduce by valve load)
Ignitor Load
  120 vac, 60 Hz, 500 VA
Valve Load
  120 vac, 60 Hz, 2A
Vent Load
  0.1 Amp
Line Heater
  1 Amp
Alarm Contacts (dry contacts)
  24V, AC/DC, 2 Amps
Operating Temperature Limits
  +32°F to + 140°F
Storage Temperature Limits
  -40°F to +185°F
Thermostat Anticipator Current
  0.1 Amp, AC
Agencies
  UL Recognized (US & Canada)

Introduction

<

Chapter 1: Installation

 

Chapter 2: Set Up

 

Chapter 3: Start Up

 

Chapter 4: Status Icons & Screen Messages

 

Chapter 5: Fault History

 

Chapter 6: Trouble Shooting

 

 

 

Click Here for training videos on the previous generation 70200

Residential:

6-Wire (Recommended Wiring)

3-Wire (Replacement Wiring)