CAP System Kit
Combustion Air Proving Kit (with Burner Cut-Off)

The Carlin CAP (Combustion Air Proving) System — A Superior Solution for Meeting Combustion Air Code Requirements.
Patent Pending
The Carlin CAP System is designed to meet code requirements for combustion air without the need to flood cold, outside air into the basement.
The CAP System is designed for Carlin residential oil burners. It may look like a simple outside air kit, but it’s more than that. ‘CAP’ stands for Combustion Air Proving. The CAP System monitors the outside air flowing into the burner cover. If the air should become blocked, the CAP system will safely shut down the burner. This safety mechanism allows the CAP system to meet NFPA code requirements for supplying combustion air to oil burners in most situations.
The CAP system installs in minutes on any Carlin residential oil burner. Carlin offers kits for uncovered burners and for burners that already have covers. The installation is quick, with wiring limited to two leads that connect directly to the primary control on the burner.
A closer look at the code requirements: NFPA-31 requires all burners installed in confined spaces be provided with combustion air. A confined space is defined as 50 cubic feet per 1000 BTU of burner input. So, an 80,000 BTU boiler -for example – would require 4,000 cubic feet of space for combustion air. If the ceiling height is 8 feet, that would be roughly 22 feet by 22 feet of empty basement. This is why so many inspectors are requiring installation of fan inducers to provide combustion air.
But, with the CAP system, there is now a better solution. Recent changes in the code allow for air intake systems that have safeguards that turn the burner off if the incoming air is blocked. With the CAP system, the confined space requirements can be cut in half. So, that 4,000 cubic feet needed for the 80,000 BTU boiler can be reduced to 2,000. For most installations, that will prevent the need to install a fan inducer that brings unwanted cold air into the basement.
But remember, the CAP System only works on a Carlin burner, so make sure to specify Carlin on all of your oil appliances. The next time you need to meet combustion air requirements, you’ll be happy you did.
The Carlin CAP System provides code compliant piece of mind!
• Easily Installed
• Building Code Compliant*
• Preferred by Homeowners
*Designed to meet NFPA31, section 5.4.3.3, as covered by April 2019 TIA 16-2
Patent Pending
CAP Model |
Description |
Firing Rate (GPH) |
Kit Contains |
| 51300AS | Low Rate CAP Kit
(for Carlin burners with covers) |
0.50 – 1.00 | Air Pressure Switch Assembly with 50806A Switch
Combustion Air Inlet Connecting Flange Cover Seal Kit Air Pressure Switch Wiring Harness 3″ Pipe Elbow w/ Birdscreen |
| 51300BS | Medium Rate CAP Kit
(for Carlin burners with covers) |
1.05 – 1.45 | Air Pressure Switch Assembly with 50806B Switch
Combustion Air Inlet Connecting Flange Cover Seal Kit Air Pressure Switch Wiring Harness 3″ Pipe Elbow w/ Birdscreen |
| 51300CS | High Rate CAP Kit
(for Carlin burners with covers) |
1.50 – 2.00 | Air Pressure Switch Assembly with 50806C Switch
Combustion Air Inlet, Connecting Flange Cover Seal Kit Air Pressure Switch Wiring Harness 3″ Pipe Elbow w/ Birdscreen |
| 51300S | Complete CAP System Kit
(for Carlin burners without covers) |
0.50 – 2.00 | Air Pressure Switch Assembly with 50806A, B & C Switches
Combustion Air Inlet Connecting Flange Cover Seal Kit Cover Cover Back Plate Air Pressure Switch Wiring Harness 3″ Pipe Elbow w/ Birdscreen |