014 – IGNITOR TESTING & TROUBLESHOOTING

This test procedure consists of three tests. The first test should be the ignitor spark test. The second test is a secondary coil resistance test. The third test consists of an input current test. The following is a step by step procedure to perform these tests. It is important that all three of these tests [...]

014 – IGNITOR TESTING & TROUBLESHOOTING2012-10-20T01:54:16-04:00

013 – RESPONDING TO CONTROL LOCKOUT CALLS

  Direct Vent Issues: With the introduction of direct vent equipment, a variety of installation and service issues are being confronted. Primary among these are cross contamination and cold combustion air. On 12/26/02, we issued a Technical Service Bulletin addressing the problem of cross contamination. This is most often seen with concentric terminations (one penetration [...]

013 – RESPONDING TO CONTROL LOCKOUT CALLS2020-08-13T15:06:47-04:00

012 – DIRECT VENT APPLICATIONS AND CROSS CONTAMINATION

The increased use of direct vent appliances in the past five years has brought with it a variety of challenges/problems for the heating industry. A direct vent appliance uses neither a chimney nor a power venter. Flue gases are vented directly through the sidewall of the building using the burner to provide the necessary draft. [...]

012 – DIRECT VENT APPLICATIONS AND CROSS CONTAMINATION2020-08-13T15:06:47-04:00

011 – WARNING OF MIS-WIRING POTENTIAL WITH HONEYWELL 7184P AND 8184P VALVE DELAY ON / MOTOR DELAY OFF (PRE / POST PURGE) CONTROLS

In a technical bulletin published by another burner manufacturer an explanation of the wiring colors for pre/post purge cad cell controls was given. That bulletin stated that the limit wire on the control was "commonly red" and the L1 power was "commonly black". I feel it is IMPERATIVE that I correct that statement to avoid [...]

011 – WARNING OF MIS-WIRING POTENTIAL WITH HONEYWELL 7184P AND 8184P VALVE DELAY ON / MOTOR DELAY OFF (PRE / POST PURGE) CONTROLS2020-08-13T15:06:48-04:00

010 – THE IMPORTANCE OF REPLACING PRE / POST PURGE, INTERRUPTED DUTY IGNITION CONTROLS WITH PRE / POST PURGE, INTERRUPTED DUTY IGNITION CONTROLS

Did you ever wonder why many of the largest cast iron boiler manufacturers in the country are making pre/post purge, interrupted duty ignition cad cell controls STANDARD on their oil fired residential boilers? These controls offer micro-processor based operating systems, pre-purge, post-purge, interrupted duty ignition, fifteen second safety timings, alarm contacts, diagnostic LED lights, serviceman [...]

010 – THE IMPORTANCE OF REPLACING PRE / POST PURGE, INTERRUPTED DUTY IGNITION CONTROLS WITH PRE / POST PURGE, INTERRUPTED DUTY IGNITION CONTROLS2020-08-13T15:06:48-04:00